Designed specifically to suit installations where ceiling space is at a premium, our Slim-Line Ducted series has unparalleled flexibility and freedom of design.
Available in Reverse Cycle (Heating & Cooling) Capacities 5.0kW, 6.0kW, 7.1kW, 8.5kW, 10.0kW, 12.5kW, 14.0kW RefrigerantDesigned specifically to suit installations where ceiling space is at a premium, our Slim-Line Ducted series has unparalleled flexibility and freedom of design.
Ideal for narrow ceiling spaces or under the floor, this ducted system meets the challenges of modern commercial and medium density apartment development.
Minimum EnergyAll Daikin air conditioners exceed MEPS requirements, in line with Daikin’s commitment to providing energy efficient, quiet, simple to use and reliable air conditioning solutions.
It's the unique features of Daikin products that makes us the world leader.
DC fan with an static pressure of 150Pa and up to 85m (100-140 Class) of available pipe run to suit your design layout.
Provides a cost effective and convenient upgrade from an existing R22 ducted system whilst retaining the field piping.
Allows the fan speed to adjust automatically to suit your duct design for optimum airflow distribution.
Daikin was recently awarded Australia’s Most Trusted Brand for Air Conditioners! We’re proud that thousands of Australians put their trust in our brand!
--> Learn More --> --> --> -->
Clear large, easy to read text with a intuitive interface.
Program on and off times to suit your lifestyle.
Automatically turns your air conditioner on when the room temperatures drops below 10°C.
Temporarily increase air conditioning power to rapidly reach your desired set point temperature.
Predefine a temperature range for cooling or heating cycles for reduced energy consumption.
Automatically turns you air conditioner off after operating for a predefined time (30-180 mins).
Quick and easy means to set up the operations of your unit.
Clear large, easy to read text with a intuitive interface.
Control up to 8 zones, each zone can be turned on or off depending on your requirements. (Requires Zone Controller)
Program on and off times, including when to open/close zones and the temperature sensor to use.
Allows the unit to automatically switch between heating and cooling for year round comfort.
Automatic notification when filter cleaning may be required.
Quick and easy means to set up the operations of your unit.
Automatic notification when filter cleaning may be required.
Each operation is colour-coded for easy association
Control up to 8 zones, each zone can be turned on or off depending on your requirements. (Requires Zone Controller)
Turn on or off the zones in your home (requires Zone Controller)
Customize the name of the zones through your home. (Zone Controller Required)
Daikin's 5-year parts and labour warranty applies to split, multi split and ducted air conditioners purchased and installed in homes across Australia
By adopting the use of 5mm heat exchanger pipe, Daikin’s slim-line ducted was able to achieve an industry leading low profile height of 245mm.
Condensate drain pump with a lift of up to 850mm is built into the unit without sacrifice to the unit’s slim form factor.
Coupled with DC fan motor and smart control logic, fan speed can be automatically adjusted to suit your duct design for simplified commissioning.
By utilising high power permanent magnets instead of induced magnetism of conventional AC motors, Daikin’s DC motor can deliver significantly higher motor efficiency.
A Daikin ducted system provides discreet air conditioned comfort throughout your entire home. It can be installed in a new home or tailored to suit an existing one, and once installed, only the controller, the return air and discharge grilles are visible inside your home.
Series | Premium Inverter | Inverter | ||||||||
Indoor Unit | FBA50BAVMA | FBA60BAVMA | FBA71BVMA | FBA85BVMA | FBA100BVMA | FBA125BVMA | FBA140BVMA | FBA71BVMA | FBA85BVMA | |
Outdoor Unit | RZAV50C2V1 | RZAV60C2V1 | RZAV71C2V1 | RZAV85C2V1 | RZAV100F2V1 | RZAV125F2V1 | RZAV140F2V1 | RZAC71C2V1 | RZAC85C2V1 | |
Rated Capacity | Cool (kW) | 5.0 | 6.0 | 7.1 | 8.5 | 10.0 | 12.5 | 14.0 | 7.1 | 8.5 |
Heat (kW) | 6.0 | 7.1 | 8.0 | 10.0 | 12.0 | 15.0 | 16.5 | 8.0 | 10.0 | |
Capacity Range | Cool (kW) | 1.4-6.0 | 1.4-7.1 | 3.2-8.0 | 4.0-10.0 | 3.5-11.5 | 3.5-14.0 | 3.5-15.0 | 1.8-8.0 | 3.2-10.0 |
Heat (kW) | 1.4-7.1 | 1.4-8.0 | 3.5-9.0 | 4.1-11.2 | 3.5-14.0 | 3.5-16.5 | 3.5-18.0 | 2.0-9.0 | 3.5-11.2 | |
Power Input (Rated) | Cool (kW) | 1.37 | 1.67 | 2.02 | 2.30 | 2.79 | 3.68 | 4.28 | 2.15 | 2.64 |
Heat (kW) | 1.41 | 1.71 | 1.99 | 2.50 | 2.92 | 3.88 | 4.52 | 2.30 | 2.95 | |
E.E.R/C.O.P | C/H | 3.65/4.26 | 3.59/4.15 | 3.51/4.02 | 3.70/4.00 | 3.58/4.11 | 3.40/3.87 | 3.27/3.65 | 3.30/3.47 | 3.22/3.39 |
TCSPF (Residential) | Hot/Average/Cold | 4.63/3.87/3.83 | 4.58/3.92/3.91 | 4.52/3.97/4.00 | 4.79/4.26/4.31 | 5.55/4.92/5.07 | 5.03/4.62/4.76 | 4.90/4.53/4.69 | 4.18/3.67/3.69 | 4.32/3.87/3.95 |
HSPF (Residential) | Hot/Average/Cold | 5.01/4.57/4.11 | 4.94/4.47/3.96 | 4.49/4.14/3.71 | 4.64/4.27/3.87 | 5.57/4.75/4.18 | 5.32/4.49/3.88 | 5.24/4.35/3.77 | 3.96/3.68/3.42 | 4.24/3.83/3.49 |
Airflow Rate (Nominal) | l/s | 300 | 300 | 383 | 533 | 533 | 600 | 600 | 383 | 533 |
Indoor Sound Level (H) @ 1.5m | dBA | 35 | 35 | 38 | 38 | 38 | 40 | 40 | 38 | 38 |
Piping Length | m | 50 | 75 | 85 | 50 | |||||
Indoor Fan Speeds | H/M/L | |||||||||
Dimensions (HxWxD) | Indoor (mm) | 245x1000x800 | 245x1400x800 | 245x1000x800 | 245x1400x800 | |||||
Outdoor (mm) | 595x845x300 | 990x940x320 | 870x1100x460 | 595x845x300 | 990x940x320 | |||||
Weight | Indoor (kg) | 37 | 37 | 37 | 47 | 47 | 47 | 47 | 37 | 47 |
Outdoor (kg) | 45 | 45 | 69 | 78 | 93 | 95 | 95 | 45 | 69 | |
Power Supply | V/Hz | 1 Phase, 220-240V, 50Hz | ||||||||
Compressor Type | Hermetically Sealed Swing Type | |||||||||
Refrigerant | R32 | |||||||||
Pipe Sizes | Liquid (mm) | 6.4 (Flared) | 9.5 (Flared) | |||||||
Gas (mm) | 12.7 (Flared) | 15.9 (Flared) | ||||||||
Drain (mm) | ID 25 / OD 32 | |||||||||
Supply Air Opening | mm (HxW, Flange) | 176x792 | 176x1192 | 176x792 | 176x1192 | |||||
Return Air Opening | mm (HxW, Flange) | 208x952 | 208x1352 | 208x952 | 208x1352 | |||||
Outdoor Operating Range | Cool (°CDB) | -5 to 50 | -5 to 46 | |||||||
Heat (°CWB) | -15 to 16 | |||||||||
EPA Sound Power Level | dBA | 68 | 68 | 67 | 71 | 68 | 69 | 70 | 68 | 70 |
Outdoor Sound Level (H) @ 1m | Pressure dBA (C/H) | 48/51 | 48/51 | 48/50 | 52/53 | 49/50 | 50/51 | 52/53 | 48/51 | 51/54 |